Summary
Title of Category
Product Family:
Application of Product:
Comparable WindStrong Products:
Sash Construction:
Nailing Fin:
Standard J Channel:
Standard Brick Mould:
Sloped Sill:
Balance System:
Lift Rail Placement:
Standard Grill:
Continuous Head and Sill:
Overall Frame Depth:
Nail Fin Set Back:
Interior Jamb Depth:
Glass Package:
Egress Size:
Information
Premium Patio Door Window
New Construction
Call your salesman for details.
Fusion welded
Integral
3/4" Pocket
180°
5° Aluminum Thermal BreakStandard
N/A
N/A
13/16" Flat
Yes
6
1 5/16"
4 9/16"
3/4"
N/A
Options
Title of Category
Colors:
Sash Size Proportions:
Applied Nail Fin:
Extended Jambs:
Low-e Options:
Gas Filled:
Tint and Obscure Options:
Double Strength:
Tempered Glass
(Any unit over 96" in height or width and any unit over 32 sq ft must be tempered):
Information
White/Tan/Earthone--Exterior paint available
Equal
(50/50)
Integral
6 9/16" Primed Wood
Cardinal 270 and Cardinal 366
Argon
Obscure, Niagara, Bronze, Gray
Available
Available
Grille and Screen Options Available:
Grille Types:
Grille Patterns:
Screen Size:
Screen Mesh:
13/16" Flat Bar
Colonial, Prairie, Ladder, Diamond, Custom
Half Screen
BetterVue Charcoal Fiber Glass, Wire
Specifications
To get a PDF file with
Specifications of the 8005 patio door.
Thermal Report
Thermal reports are generated when a test specimen is physically attached to a wall and thermocouples are installed to measure the actual about of heat (BTU's) that is lost with a standard temperature differential.
We are transparent with our engineering data because we know the value of our windows. For those that are so inclined, go to
Thermal Reports to see the actual test data report from our independent Laboratory. We use NCTL (National Certified Testing Laboratory) to independently provide all of our test data.
Test Laboratory: National Certified Testing Laboratories (NCTL)
Test Method: NFRC 102-2004 "Procedure for Measuring the Steady-State Thermal Transmittance of Fenestration Systems."
Results:
excerpt..."Based on test results, the standardized thermal transmittance of the test specimen (UST) was determined to be 0.32 BTU/hr/ft2/oF."
Structural Test Report
<
We are transparent with our engineering data because we know the value of our windows. For those that are so inclined, go to
Structural Test Report to see the actual test data report from our independent Laboratory.
We used Architectural Testing Laboratory to independently provide all of our test data.
ANSI/AAMA/NWWDA 101/I.S.2-97, Voluntary Specifications
for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors
Size
Air Infiltration
Water Resistance
Structural Test
73" x 80 1/4"
0.28 cfm/ft2
5.25 (25 mph) psf
52.5 psf
SGD-R35 (6068)
SGD-R35 (6068)
|