6010NJ Single Hung Window
-
Summary
-
Options
-
Specifications
-
Thermal Report
-
Thermal Simulation
-
Structural Report.
-
Sizing
-
Egress Chart
-
STC Ratings
-
Submittal
Summary
Title of Category
Product Family:
Application of Product:
Comparable WindStrong Products:
Sash Construction:
Nailing Fin:
Standard J Channel:
Standard Brick Mould:
Sloped Sill:
Balance System:
Lift Rail Placement:
Standard Grill:
Continuous Head and Sill:
Overall Frame Depth:
Nail Fin Set Back:
Interior Jamb Depth:
Glass Package:
Egress Size:
Information
Premium Single Hung Window
New Construction
6060
Fusion Weld
Integral
3/4" Pocket
180°
5° Standard
Block and Tackle
Equal, Oriel and/or Cottage
13/16" Flat
Yes
2 15/16"
1 1/16"
1 13/16"
3/4"
3-0 x 5-0 Equal
Options
Title of Category
Colors:
Sash Size Proportions:
Applied Nail Fin:
Extended Jambs:
Low-e Options:
Gas Filled:
Tint and Obscure Options:
Double Strength:
Tempered Glass
(Any unit over 96" in height or width and any unit over 32 sq ft must be tempered):
Information
White/Tan/Earthone--Exterior paint available, Bronze exterior in stock
Equal
(50/50), Cottage
(40/60), Oriel
(60/40)
Integral
4 9/16" or 6 9/16" Primed Wood
Cardinal 270 and Cardinal 366
Argon
Obscure, Niagara, Bronze, Gray
Available
Available
Grille and Screen Options Available:
Grille Types:
Grille Patterns:
Screen Size:
Screen Mesh:
13/16" Flat Bar
Colonial, Prairie, Ladder, Diamond, Custom
Half Screen
BetterVue Charcoal Fiber Glass, Wire
Specifications
To get a PDF file with Specifications of the 6010NJ Single hung.
Thermal Report
Thermal reports are generated when a test specimen is physically attached to a wall and thermocouples are installed to measure the actual about of heat (BTU's) that is lost with a standard temperature differential.
We are transparent with our engineering data because we know the value of our windows. For those that are so inclined, go to
Thermal Reports to see the actual test data report from our independent Laboratory. We use NCTL (National Certified Testing Laboratory) to independently provide all of our test data.
Test Laboratory: National Certified Testing Laboratories (NCTL)
Test Method: NFRC 102-2004 "Procedure for Measuring the Steady-State Thermal Transmittance of Fenestration Systems."
Results:
excerpt..."Based on test results, the standardized thermal transmittance of the test specimen (UST) was determined to be 0.39 BTU/hr/ft2/oF."
Thermal Simulations
We are transparent with our engineering data because we know the value of our windows. For those that are so inclined, go to
Thermal Simulations to see the actual test data report from our independent Laboratory. We use NCTL (National Certified Testing Laboratory) to independently provide all of our test data.
Glass Configuration U-Factor Condensation Solar Visual
Resistance Heat Gain(SHGC) Transmittance
2mm Clear (SSB-Single Strength)
3mm Clear (DSB-Double Strength)
2mm Low-e (2nd surface)
2mm Low-e (3rd surface)
3mm Low-e (2nd surface)
3mm Low-e (3rd surface)
0.50
0.50
0.31
0.31
0.31
0.31
41.0
41.0
56.0
56.0
56.0
56.0
0.65
0.64
0.34
0.22
0.41
0.32
0.67
0.66
0.59
0.53
0.59
0.53
|
The Solar Heat Gain Coefficient (SHGC) measures how well a window blocks heat from sunlight. The SHGC is the fraction of the heat from the sun that enters through a window. SHGC is expressed as a number between 0 and 1. The lower a window''s SHGC, the less solar heat it transmits. Put another way, the lower the SHGC, the more resistant to solar heat gain.
Read more about SHGC...
Structural Test Report
We are transparent with our engineering data because we know the value of our windows. For those that are so
inclined, go to to the Structural Test Report tosee the actual test data report from our independent
Laboratory. We used Architectural Testing Laboratory to independently provide all of our test data.
AAMA/WDMA/CSA 101/I.S.2, Voluntary Specifications
for Aluminum, Vinyl (PVC) and Wood Windows and Glass Doors
48" x 75"
0.02 cfm/ft2
6.75 psf
25 psf
H-R45
H-R25
|
48" x 60"
0.02 cfm/ft2
7.5 psf
40 psf
H-R50
H-R40
|
36" x 72"
0.05 cfm/ft2
6.00 psf
40 psf
H-R40
H-R35
|
STC-Sound Transmission Coefficient reports
STC 26